Digest for sci.electronics.repair@googlegroups.com - 16 updates in 2 topics

etpm@whidbey.com: Aug 24 10:07AM -0700

On Thu, 22 Aug 2019 09:02:25 -0700, Jeff Liebermann <jeffl@cruzio.com>
wrote:
 
>>Eric
 
>Well, there might be a component failure, but let's play with the
>knobs a bit more first to see if things improve.
Well, I got time this morning to fuss with the CRT. The astigmatism
adjustment works but I cannot get the display to be as sharp on one
side of the tube as the other. I did degauss the thing too but there
was no change. Later today I'll swap the X axis wires and see if the
out of focus swaps too. If that happens then it must be the circuit
and not the CRT, right?
Thanks,
Eric
etpm@whidbey.com: Aug 24 01:25PM -0700

On Fri, 23 Aug 2019 13:30:31 -0500, Jon Elson <elson@pico-systems.com>
wrote:
 
 
>A scope could show that both plates are driven, but not sure a DVM would
>give a definitive reading.
 
>Jon
I tried swapping the X axis connections to the CRT and the out of
focus conditionn swaps too. So it is not the CRT. I'll contact the
contact the kit supplier and see what he says.
Thanks,
Eric
tabbypurr@gmail.com: Aug 24 02:47PM -0700

> contact the kit supplier and see what he says.
> Thanks,
> Eric
 
We already knew it's not the crt at fault. Another poster that asks and gets the correct answer, but remains entirely lost.
Phil Allison <pallison49@gmail.com>: Aug 24 03:17PM -0700

John Robertson wrote:
 
 
 
> However the surrounding metal could possibly get magnetized. While I
> agree it is very unlikely, it can't hurt to run a demagnetizer over the
> setup.
 
** A demagnetiser for tools is not likely to work on a steel box.
 
In any case the earth's magnetic field deflects the trace on a CRT
screen - unless the CRT is fully mu-metal shielded.
 
That is why most decent scopes have a "trace rotate" control that applies a correcting field.
 
 
> I can't see it affecting the focus though, that does sound more like a
> voltage issue, a stray magnetic field would simply deflect the beam to
> some extent, but it would not make it fuzzy.
 
** Correct.
 
> On our old B&W picture tube monitors when the HV at the anode (does this
> 'scope have an anode connection?) drops the image gets fuzzy and the
> image blooms in all directions...
 
** Yep, the spot on the face of the picture tube de-focusses and the ( magnetic ) deflection becomes excessive if even some EHT is lost.
 
The simple test for a weak HV rectifier valve was to turn up the brightness, thereby increasing electron beam current and hence loading the EHT supply.
 
OTOH colour sets and monitors usually had regulated EHT supplies.
 
 
 
.... Phil
Jeff Urban <jurb6006@gmail.com>: Aug 24 06:08PM -0700

>Scope CRTs (unlike picture tubes) never become magnetised, and >even if one did somehow it would deflect the trace not de-focus >it,
 
Nail on the head.
Jeff Urban <jurb6006@gmail.com>: Aug 24 06:13PM -0700

Get the print even if you have to scan it. Send it to me. If you cannot get my email here I will give it to you. You send it to me and I will post it where I can hotlink to it.
 
Or don't you have a scanner ? Or did you build this purely from instructions ? You're not even telling us what this contraption is.
etpm@whidbey.com: Aug 24 06:29PM -0700

>> Thanks,
>> Eric
 
>We already knew it's not the crt at fault. Another poster that asks and gets the correct answer, but remains entirely lost.
Hogwash. I went back and read all the responses to my posts about this
CRT. Most likely the CRT was not at fault but this was not known for
sure. Now I know for sure the CRT is OK. Your reply does nothing to
enlighten anybody. You have not posted anything useful. Why is that?
You posted "Presumably the electrode voltages aren't staying the same
as the thing sweeps across the screen." That's all you posted. Should
I take what you presume as being true in all situations? In any
situation? Why? And why did you presume what you did? How do I check
what you said? I'm trying to learn, what are you trying to do? If I am
lost then why not show me the way? When people ask me questions about
machining I try my best to help, often with several explanations
because some folks don't get it as easily as I do when it comes to
machining. Please, if you can't bring yourself to help then don't
waste your time responding to my posts, especially since I won't be
wasting any more of my time reading yours.
Eric
Jeff Urban <jurb6006@gmail.com>: Aug 24 08:04PM -0700

How can you build an electronic circuit without having the schematic ?
Phil Allison <pallison49@gmail.com>: Aug 24 11:17PM -0700

et...@whidbey.com wrote:
--------------------------
** Wot a tedious wanker..
 
 
 
> >We already knew it's not the crt at fault. Another poster that
> > asks and gets the correct answer, but remains entirely lost.
 
> Hogwash.
 
** Nope - those hogs are not in need of any washing .
 
 
> enlighten anybody. You have not posted anything useful. Why is that?
> You posted "Presumably the electrode voltages aren't staying the same
> as the thing sweeps across the screen." That's all you posted.
 
** That is VERY good answer.
 
Every half decent CRT scope made uses balanced drive to the deflection plates - vertical and horizontal. There is a reason for doing so - it keeps the spot on the screen focussed.
 
YOU have the darn thing in front of you but are so dopey you cannot say if that is or is not the case with your simple kit scope.
 
FYI:

When I was 17 and at high school, I saved my pennies and bought all the parts to to make a basic, 2MHz, 5 tube, 3 inch CRT scope.
 
My brother in law fabricated the steel case as an 18th birthday present - I still have it and it works fine - hence my affection for analogue scopes.
 
It uses balanced drive for deflection.
 
The focus is quite good.
 
 
 
.... Phil
tabbypurr@gmail.com: Aug 25 12:31AM -0700

> waste your time responding to my posts, especially since I won't be
> wasting any more of my time reading yours.
> Eric
 
Then I won't spend any further time clarifying either. Fool.
Jeff Urban <jurb6006@gmail.com>: Aug 25 12:54AM -0700

>We already knew it's not the crt at fault.
 
How ?
 
How can he know that, does he have a spare that acts exactly the same ? If so out with it.
 
I put it 50/50 between the CRT and the deflection drive.
 
And what the hell is this thing ? A dental scale ? A DVD rewinder ? What ?
 
Knows the CRT is not at fault, well then every voltage and waveform should be known to him. Is the plate drive balanced ? Can we at least know that ?
Trevor Wilson <trevor@rageaudio.com.au>: Aug 25 07:11PM +1000

On 25/08/2019 4:17 pm, Phil Allison wrote:
 
 
> My brother in law fabricated the steel case as an 18th birthday present - I still have it and it works fine - hence my affection for analogue scopes.
 
 
**Try a Rigol DS1054z. A very impressive 'scope for not too much cash
and way better than the preceding Rigol (which, if I recall correctly
you own/ed). My old Tek analogue 'scope has sat idle for a long time.
Like you, I love my old analogue 'scopes (put a bid in for a Tek 7704
last week and lost the auction), but for daily use, the Rigol is
unbeatable.
 
--
Trevor Wilson
www.rageaudio.com.au
 
---
This email has been checked for viruses by Avast antivirus software.
https://www.avast.com/antivirus
Fox's Mercantile <jdangus@att.net>: Aug 25 06:42AM -0500

> We already knew it's not the crt at fault. Another poster
> that asks and gets the correct answer, but remains entirely
> lost.
 
You just have to act like a cunt don't you?
 
 
--
"I am a river to my people."
Jeff-1.0
WA6FWi
http:foxsmercantile.com
tabbypurr@gmail.com: Aug 25 08:47AM -0700

On Sunday, 25 August 2019 12:42:46 UTC+1, Fox's Mercantile wrote:
> > that asks and gets the correct answer, but remains entirely
> > lost.
 
> You just have to act like a cunt don't you?
 
Let's see. I explained what the problem almost certainly was and how to find it. The OP ignored it. I pointed out that I'd already explained it, the op was then simply rude. So I declined to assist further. Shrug, what more do you want?
 
 
NT
Andy Burns <usenet@andyburns.uk>: Aug 25 04:57PM +0100

Trevor Wilson wrote:
 
> Try a Rigol DS1054z. A very impressive 'scope for not too much cash
 
And easily hackable to add extra bandwidth and features.
N_Cook <diverse@tcp.co.uk>: Aug 25 02:17PM +0100

On 24/08/2019 16:18, N_Cook wrote:
> than analyser ,for easier taking of pairs of readings/ LCD display
> decoding look-up table determination , for the full set. There may be
> transcription errors in the above of course.
 
For units decodng
 
From the previous, for unit=1 eg 1.264
R=0,0,4,0,5,0,8,0,0,8,
S=1,0,0,8,4,0,8,0,0,4,
T=1,0,0,8,F,0,8,0,0,C,
 
unit is more simply represented by the first term of each of R,S and T
string and so preliminary look-up table
unit ~ SPI R(1) , S (1) , T(1)
1~ 0,1,1
2~ 3,2,1
5~ 1,3,2
6~ 3,3,2
8~ 3,3,3
9~ 1,3,3
10~ 3,5,7 (or maybe 0) , (plus 3,4 and 7 also unknown so far)
and the remaining 9 terms of R,S and T are invariant for the readings
taken so far.
 
When the sun goes down a bit, I'll try some pairings in the range 10 to
50 metres, for 10s decoding
 
--
Monthly public talks on science topics, Hampshire , England
<http://diverse.4mg.com/scicaf.htm>
You received this digest because you're subscribed to updates for this group. You can change your settings on the group membership page.
To unsubscribe from this group and stop receiving emails from it send an email to sci.electronics.repair+unsubscribe@googlegroups.com.

Digest for sci.electronics.repair@googlegroups.com - 5 updates in 2 topics

Jon Elson <elson@pico-systems.com>: Aug 23 01:30PM -0500

On Thu, 22 Aug 2019 12:11:57 -0700, etpm wrote:
 
> I dunno Jon. How would I tell? Measure voltage to ground and see if one
> or both changes?
> Eric
 
If they have a centering pot that drives one deflection plate, and some
amplifier that drives ONLY the other plate, then that is single-ended
deflection drive. if they have differential amplifiers that drive both
plates in opposite directions, then that would be differential.
 
A scope could show that both plates are driven, but not sure a DVM would
give a definitive reading.
 
Jon
tabbypurr@gmail.com: Aug 23 12:27PM -0700

> need to be degaussed. I have a demagnetizer designed for demagnetizing
> tools. I'm sure it would work to degauss a CRT.
> Eric
 
Posting us a schematic would help, but you don't have one. Stating he obvious here you should look at any variation in focus voltage at the horizontal sweep speed.
 
Generally speaking Russian CRTs are perfectly capable.
 
 
NT
Phil Allison <pallison49@gmail.com>: Aug 23 06:03PM -0700

Some fucking idiot called "Eric" wrote:
--------------------------------------
> need to be degaussed. I have a demagnetizer designed for demagnetizing
> tools. I'm sure it would work to degauss a CRT.
> Eric
 
** Total stupidity.
 
Scope CRTs (unlike picture tubes) never become magnetised, and even if one did somehow it would deflect the trace not de-focus it,
 
 
 
.... Phil
John Robertson <spam@flippers.com>: Aug 24 08:45AM -0700

On 2019/08/23 6:03 p.m., Phil Allison wrote:
 
> Scope CRTs (unlike picture tubes) never become magnetised, and even if one did somehow it would deflect the trace not de-focus it,
 
> ..... Phil
 
However the surrounding metal could possibly get magnetized. While I
agree it is very unlikely, it can't hurt to run a demagnetizer over the
setup.
 
I can't see it affecting the focus though, that does sound more like a
voltage issue, a stray magnetic field would simply deflect the beam to
some extent, but it would not make it fuzzy.
 
On our old B&W picture tube monitors when the HV at the anode (does this
'scope have an anode connection?) drops the image gets fuzzy and the
image blooms in all directions...
 
John :-#)#
N_Cook <diverse@tcp.co.uk>: Aug 24 04:18PM +0100

On 06/08/2019 17:26, N_Cook wrote:
> heights, averaging to about true presumably oe t least offsettable. A
> "proper" geodometer with interface topc is far too expensive for this
> sort of project.
 
Decoding so far, for anyone else doing similar (J makes an ideal search
engine term along with SZYCLCD.COM and ident YGFB178004-A1). 12MHz
sampling and 20 M samples per run on the analyser with d0 line for
trigger. SPI protocol with d3 as clock,d0 as MISO, d4 as MOSI, 4 bit
word length so superfluous analyser 8bit zeros removed in the following.
d1 and d2 only active during power-up page , not in measure mode.
For clarity and reduction, repeats in the coding via the following
look-up table.
 
J=
4,F,D,8,8,D,D,4,1,E,8,C,6,0,C,2,A,0,2,0,5,0,9,2,C,B,1,1,1,1,1,1,1,1,6,0,7,C,8,0,0,0,
K= 3,0,0,0,0,0,0,0,0,0,0,0,0,0,
L= 2,0,0,0,4,0,7,0,8,0,0,8,
N=2,0,A,0,0,8,4,0,8,0,0,4,
P=0,0,0,0,0,0,0,0,8,0,0,0,
Q=8,A,0,0,0,8,F,0,8,0,0,C,
R=0,0,4,0,5,0,8,0,0,8,
S=1,0,0,8,4,0,8,0,0,4,
T=1,0,0,8,F,0,8,0,0,C,
U=0,0,0,0,0,0,
 
Assuming J is invariant for this make and model in question, about 20
readings so far in the 1.000 to 2.000 display range ,it is invariant,
L to U would contain variation for units ,hundreds and thousands, DPs
and nulls and probably annunciators and other display rows data for the
other 3 lines in the display.
 
Single example of coding for the reading 1.264 in the bottom line for
the frames sent on pressing "measure" , running the analyser after
power-up each time and d0 line trigger occuring after pressing "measure"
, second frame is repeat of the first, powering down the measurer after
each reading.
1.264
J,K
L,K
N,K
Q,K
P,K
2,D,R,K
6,B,S,K
C,E,T,K
8,7,U,
J,K
2,D,R,K
6,B,S,K
C,E,T,K
8,7,U,
 
Preliminary decoding for readings in the range 1.0.. to 1.7..
for tenths in the rank P,K,*,x,R,K,*.y,S,K after the primary ident J,
where * is don't care/ignored and x,y is the coding
2 on the LCD codes to (x,y) D,B in the SPI
3 ~ D,7
5 ~ D,5
6 ~ D,D
7~ 9,7
 
for hundredths,
only *.*5* and *.*6* measures in the display so far
in the rank T,K,*,x,U
5 ~ SPI F
6 ~ 7
will probably require 1 or 2 other elements for the full set 0 to 9
 
for thousandths (for eventual use thousandths [mm] would be redundent)
R,K,x,*,S,K,y,*,T,K,z,*U
x, y, z SPI
1~ 6, 4, 0
2~ A, C, 4
3~ 6, C, 4
4~ 6, C, 8
6~ E, 8, C
7~ 6, 4, 4
8~ E, C, C
 
 
I might hookup an Arduino or a Pi , as in the intended usage , rather
than analyser ,for easier taking of pairs of readings/ LCD display
decoding look-up table determination , for the full set. There may be
transcription errors in the above of course.
 
 
 
--
Monthly public talks on science topics, Hampshire , England
<http://diverse.4mg.com/scicaf.htm>
You received this digest because you're subscribed to updates for this group. You can change your settings on the group membership page.
To unsubscribe from this group and stop receiving emails from it send an email to sci.electronics.repair+unsubscribe@googlegroups.com.

Digest for sci.electronics.repair@googlegroups.com - 9 updates in 1 topic

etpm@whidbey.com: Aug 22 10:31AM -0700

On Thu, 22 Aug 2019 09:02:25 -0700, Jeff Liebermann <jeffl@cruzio.com>
wrote:
 
>>Eric
 
>Well, there might be a component failure, but let's play with the
>knobs a bit more first to see if things improve.
I'll need to see if I can get thing to make just a straight line.
If not I can lock the display to just showing digits. Then I can
adjust the astigmatism and see if the digits on the right hand side of
the display get sharper.
I can also swap the X axis wires, which mirror images the display.
I know because I already did this accidently. If the focus problem
mirrors too then I wonder what that would mean.
I'll try the astig. adjustment first later today.
Thanks,
Eric
Jon Elson <elson@pico-systems.com>: Aug 22 01:38PM -0500

On Wed, 21 Aug 2019 16:47:10 -0700, etpm wrote:
 
> So I built a kit that uses an electrostatic deflection CRT for the
> display. It all turned out very well except the display is much more in
> focus on one side of the screen.
Do they use true differential deflection signals, or unipolar (ie one
plate of each deflection pair is held at a constant voltage)? If
unipolar, it can cause this type of trouble.
 
Jon
etpm@whidbey.com: Aug 22 12:11PM -0700

On Thu, 22 Aug 2019 13:38:15 -0500, Jon Elson <elson@pico-systems.com>
wrote:
 
>plate of each deflection pair is held at a constant voltage)? If
>unipolar, it can cause this type of trouble.
 
>Jon
I dunno Jon. How would I tell? Measure voltage to ground and see if
one or both changes?
Eric
Paul Drahn <pdrahn@jodeco.com>: Aug 22 12:48PM -0700

> I dunno Jon. How would I tell? Measure voltage to ground and see if
> one or both changes?
> Eric
 
If you physically rotate the whole device 90 degrees, does anything
change? Possible magnetic flux from your shop!
 
Paul
etpm@whidbey.com: Aug 22 01:59PM -0700

On Thu, 22 Aug 2019 12:48:31 -0700, Paul Drahn <pdrahn@jodeco.com>
wrote:
 
 
>If you physically rotate the whole device 90 degrees, does anything
>change? Possible magnetic flux from your shop!
 
>Paul
Greetings Paul,
Yeah, the CRT is especially sensitive to magnetic flux. But the thing
has the out of focus problem no matter the rotation or where I stand
in my shop. It is always less focused on one side. But thanks anyway.
I know almost nothing about tubes in general and CRTs in particular.
Eric
stratus46@yahoo.com: Aug 23 02:12AM -0700

> even?
> Anyway, thanks for any help.
> Eric
 
High Voltage on CRTs tends to use very high resistance. An 11 meg meter
could load down the test points and give faulty readings. A high Voltage probe is often around a gigohm load and cause much less disruption in the readings.
 

John-Del <ohger1s@gmail.com>: Aug 23 05:01AM -0700

> even?
> Anyway, thanks for any help.
> Eric
 
 
In theory, voltages shouldn't have any affect on the focus across the face of the CRT, but in practice, all sorts of variables happen.
 
It's indeed possible that your problem will go away if you get the CRT close to it's designed operating voltages. At least, that's what I would do before condemning the CRT as defective.
 
Is there a schematic of what you built on line?
etpm@whidbey.com: Aug 23 08:44AM -0700

On Fri, 23 Aug 2019 05:01:33 -0700 (PDT), John-Del <ohger1s@gmail.com>
wrote:
 
 
>In theory, voltages shouldn't have any affect on the focus across the face of the CRT, but in practice, all sorts of variables happen.
 
>It's indeed possible that your problem will go away if you get the CRT close to it's designed operating voltages. At least, that's what I would do before condemning the CRT as defective.
 
>Is there a schematic of what you built on line?
No, there is no schematic. Paul Drahn suggested to me that the CRT may
need to be degaussed. I have a demagnetizer designed for demagnetizing
tools. I'm sure it would work to degauss a CRT.
Eric
John Robertson <spam@flippers.com>: Aug 23 09:16AM -0700

> need to be degaussed. I have a demagnetizer designed for demagnetizing
> tools. I'm sure it would work to degauss a CRT.
> Eric
 
A Weller heavy duty soldering gun is also useful as a small degaussing
tool if you don't have a proper open coil one handy.
 
John :-#)#
 
--
(Please post followups or tech inquiries to the USENET newsgroup)
John's Jukes Ltd.
MOVED to #7 - 3979 Marine Way, Burnaby, BC, Canada V5J 5E3
(604)872-5757 (Pinballs, Jukes, Video Games)
www.flippers.com
"Old pinballers never die, they just flip out."
You received this digest because you're subscribed to updates for this group. You can change your settings on the group membership page.
To unsubscribe from this group and stop receiving emails from it send an email to sci.electronics.repair+unsubscribe@googlegroups.com.