- Tektronik 2230 oscilloscope: nasty menu? - 1 Update
- Harman Kardan AVR1700 Rcvr BCO update - 1 Update
Jean-Pierre Coulon <coulon@cacas.pam.obs-nice.fr>: Jan 07 07:40AM +0100 On Thu, 3 Jan 2019, JC wrote: > pin DIP, fairly obvious) there is a plug marked RESET. Move it to the reset > position. That will stop the digital board from running and assuming you have > no serious faults will turn the scope into an analog only scope. There is a jumper (connects 2 out of 3 pins) with the label RESET near its rightmost position. It was in this position. I moved it to the leftmost position and now everything is perfect (for me). Removing yhe case was difficult but possible after I removed the 2 screws of the little side panel and the 2 nuts of the IEEE connector. Thanks to you. :-) -- Jean-Pierre Coulon |
kapitan16103@gmail.com: Jan 06 12:19PM -0800 Hello, thank you for participating in the problem that torments many people !!! After the holidays, I will seek justice even though I live in Russia. The HK is obliged to cover all the problems by selling me such a defective receiver. |
You received this digest because you're subscribed to updates for this group. You can change your settings on the group membership page. To unsubscribe from this group and stop receiving emails from it send an email to sci.electronics.repair+unsubscribe@googlegroups.com. |
No Response to "Digest for sci.electronics.repair@googlegroups.com - 2 updates in 2 topics"