Jeff Urban <jurb6006@gmail.com>: Apr 08 10:29AM -0700

Print is available on hifiengine. This is one that has that multi voltage switching. Not getting anything. Something happened, I Tshot this thing a while back and it was a no rush, but now comes time to get it the hell outta here. I got the parts for a blown channel, put them in and dead. Actually I am relearning how to read those old PC boards. It is coming back.
 
So this one, I got continuity from the cord all the way to the voltage selector. That rules out the switch and any and all fusible devices in the way. testing for actual AC is easier said than done but if you got continuity it must be there, right ?
 
The transformer has the usual dual primaries so the odds of that being open are not high, especially both of them. And then to cut to the chase I got me a suicide cord and injected the AC straight into the one primary and got at least dial lights where before I had nothing.
 
Then I checked the plug for the selector and it has continuity where the print says it should.
 
Forty fucking years in the business and this stupid ass thing is driving me nuts(er). If I get sick of it I will figure out how to just permanently wire it for 120 volts and be done with it but I would rather not. If I can avoid it.
 
This is ridiculous, I have figured out the rewire on a bunch of PX type of equipment. (multi voltage) Like SAE when nobody could get q print, and Marantz that wouldn't give out the information to anyone but authorized service. Piece of cake. But this damn thing...
 
I even pulled on the wires on the jack for the voltage selection to see if maybe the copper inside was broken.
 
There would have to be two thermals out in the primaries for this, unless maybe one in the secondary but it is center tapped and shows continuity.
 
Another one of those things with nothing wrong but it doesn't work.
 
So I a willing to at least listen to some flippant ideas in case someone has a buzz on. This is one of those off the wall things, really.
"pfjw@aol.com" <peterwieck33@gmail.com>: Apr 08 10:51AM -0700

Continuity via a VOM is only an indicator, not proof-of-goodness. On a great many more than just a few occasions, I have gotten continuity at tester-voltages, but a line voltage - nothing. And that is where your concept of a 'thermal' issue comes into play. Especially with transformers.
 
Of course there is always the kill-or-cure spark-off - Obtain a high-value, high voltage cap and get it fully charged, this is where an old-fashioned full-voltage cap tester becomes handy. Discharge it into the suspect winding. It just might fuse that thermal failure. I have done this three (3) times, and it worked 2/3 times. The third time, the cap did discharge, but the result was 'open' even with the tester.
 
Peter Wieck
Melrose Park, PA
Ralph Mowery <rmowery28146@earthlink.net>: Apr 08 02:18PM -0400

In article <1df8cc21-cc38-47d7-98c1-d18644c964a3@googlegroups.com>,
jurb6006@gmail.com says...
 
> There would have to be two thermals out in the primaries for this, unless maybe one in the secondary but it is center tapped and shows continuity.
 
> Another one of those things with nothing wrong but it doesn't work.
 
> So I a willing to at least listen to some flippant ideas in case someone has a buzz on. This is one of those off the wall things, really.
 
You did not by any chance reverse some of the transformer wires where
they are phased so they cancel each other out ?
 
Put the ohm meter away and check for voltage with an analog meter.
John-Del <ohger1s@gmail.com>: Apr 08 01:20PM -0700

Don't take this wrong Jeff, but any chance it has a small standby transformer that drives a relay with contacts in the primary side of the main XFR?
 
Hey, we all brain fart these things on occasion.
Phil Allison <pallison49@gmail.com>: Apr 08 01:54PM -0700

Ralph Mowery wrote:
 
---------------------
 
 
> You did not by any chance reverse some of the transformer wires where
> they are phased so they cancel each other out ?
 
** Reverse connected primaries only ever results in no magnetising in the transformer core. You are then left with just the copper resistance.
 
Any attempt to operate it under that condition causes a HUGE AC supply current to flow - similar to that during an inrush surge.
 
Fuses will splat, breakers will trip.
 
 
 
.... Phil
legg <legg@nospam.magma.ca>: Apr 08 01:09PM -0400

On 6 Apr 2020 17:10:26 GMT, Allodoxaphobia <trepidation@example.net>
wrote:
 
 
>> Comments greatly desired
 
>What you want are suggestions and helpful tips.
>Self-referentially, this ng has FAR TOO many "comments".
 
In 2013.
 
RL
You received this digest because you're subscribed to updates for this group. You can change your settings on the group membership page.
To unsubscribe from this group and stop receiving emails from it send an email to sci.electronics.repair+unsubscribe@googlegroups.com.

No Response to "Digest for sci.electronics.repair@googlegroups.com - 6 updates in 2 topics"

Post a Comment