Connie <caedfaa9ed1216d60ef78a6f660f5f85_9556@example.com>: Apr 13 06:44PM

replying to Dan, Connie wrote:
How do u do this. Mine does the exact same thing and it used to go lower than
69.
 
--
posted from
http://www.homeownershub.com/maintenance/adjustiing-mod-ing-digital-thermostat-on-lg-window-air-condi-116541-.htm
Tim R <timothy42b@aol.com>: Apr 13 07:08PM -0700

You're focused on the electronics but we really need some physical data.
 
What is the delta T? (what is the temperature of the air entering the air conditioner and what is the temperature of the air being supplied to the room)
 
Refrigerant charges are weighed in (if the maker is careful) or just estimated if not. Either way it is possible to customize them for the actual use scenario based on superheat and subcooling measurements.